Hmm... They added the wire by notching the box and putting a cover plate on. Also the wire was just surface mounted. http://t.co/ZTjD6RQ
It helps if all the wire is in the electrical box. They also cut the ground wire. So much for doing it right the... http://t.co/PQAaMiw
Missing k/o's on the round bell box. Missing conduit on the wire to the box. Said thing is this was open like this... http://t.co/mq6JGBC
Red neck wiring. Instead of getting the right photo eye they just taped one onto the post. http://t.co/jWhg7Qj
Cutting open the wall for a new electrical panel. Doing so found a nice surprise. Two buried junction boxes. No... http://t.co/D4bReQk
Here's what the electrical panel looked like inside the house from the fallen tree limb. http://t.co/2jPrzLo
This is why you have PUD cut the tree limbs around your overhead power lines. Totally ripped the wall up. http://t.co/oldnR1P
The buss bar with a bad connection to the breaker. Common in older panels. http://t.co/9wsjSDT
Found a bad breaker with loose connection on the buss bar. The home owner could smell something burning but... http://t.co/C0jjutw
All electrical boxes are to have covers. One to contain a fire in the electrical box and also keep things out. http://t.co/NYQSjjD
No bushing on the rigid nipple. The metal is digging into the conductor and not protected by a breaker. When the... http://t.co/PpzRJ8D
Most lugs are not rated for double taps like what you see here. To top that.. They cut many of the strands to... http://t.co/3dl1HrW
In stead of installing this wire connection in a box they just taped it up. This wire is not rated for open air... http://t.co/PMpXrMv
Hard to believe this still exist in homes today. Time to bring it up to code. http://t.co/y1jaSJb
20 year old plug outlet that had loose connections. It's recommended you replace old outlets to eliminate fire... http://t.co/1Dznquw
A loose connection at a light fixture. To top that off they were using 100 watt light bulbs when the fixture was... http://t.co/VUwxNTp
A buried in the wall electrical splice. Owner was doing a kitchen remodel and we found this surprise in the wall.... http://t.co/JNHIivE
Another reason to check all the connections in the electrical panel. http://t.co/8AcbLef
When making electrical connections, make sure they are installed in electrical junction boxes. This is a fire... http://t.co/5NluB8c
Check your connections at the breakers so this won't happen to you. The wire was just touching the breaker screw... http://t.co/4YxDh5K
They have a Federal Pacific Panel and the breaker did not trip. Also have no smoke detectors. They were lucky. http://fb.me/IyQW4BFx
Teamabsoluteelectric
Hitsquadbasebal
This is why ARC Fault Protection is required in bedrooms. The plug outlet was starting to burn on the back side.... http://fb.me/U5qxX1aJ
A result of a power surge. Make sure your home has whole house surge protection. You can imagine what would happen... http://fb.me/QxnHwIs9
I posted a new photo to Facebook http://fb.me/Kaxm8KhH
www.absoluteelectricinc.com - New Site!! New Look!! Let Me Know What You Think!! Also Please Leave Me a Review!! http://fb.me/EXMYTbdt
Local Electrical Services Clark County Washington: Absolute Electric, we believe in quality without compromise. Wh... http://absoluteelectricinc.loc...
Local Electrical Services Camas Washington: Absolute Electric, we have in been in business since 1996. And for the... http://absoluteelectricinc.loc...
Other ways to read this feed:Feed readerFacebook